EchoPod®
UG01 & UG03

Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer

Reliable Measurement
Horizontal Transducer



Signal Attenuation
Range: UG01: 1.5” to 4.9’ (3.8cm to 1.5m), UG03: 4” to 9.8’ (10.1cm to 3m)
Accuracy: UG01: 0.125” (3mm), UG03: ± 0.2% of range
Resolution: UG01: 0.019” (0.5mm), UG03: 0.039” (1mm)
Dead band: UG01: 1.5” (3.8cm), UG03: 4” (10.1cm)
Beam width: 2” (5cm)
Configuration: WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Supply voltage: 14-28 VDC
Max. consumption: 0.5W
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Contact type: (4) SPST relays
Contact rating: 60 VA, 1A maximum
Contact fail-safe: Open, closed, hold last
Contact hysteresis: Selectable
Process temp.: F: -40º to 176º, C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º, C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Cable jacket mat.: Polyurethane
Cable type: 9-conductor, shielded
Cable length: 48” (1.2m)
Process mount: -0001: 2” NPT, -0011: 2” G
Mount gasket: -0001: N/a, -0011: Viton®
Classification: General purpose
Approval: UL 61010-1
Compliance: CE, RoHS
EchoPod®
UG06 & UG012

Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer



Reliable Measurement
Horizontal Transducer



Signal Attenuation
Range: UG06: 8” to 19.6’ (20cm to 6m), UG12: 18” to 39.3’ (45.7cm to 12m)
Accuracy: ± 0.2% of range
Resolution: UG06: 0.079” (2mm), UG12: 0.196” (5mm)
Dead band: UG06: 8” (20.3cm), UG12: 18” (45.7cm)
Beam width: UG06: 3” (7.6cm), UG12: 6” (15.2cm)
Configuration: Push button or WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Display type: LCD, 6-digit
Display units: Inch, cm or percent
Supply voltage: 14-28 VDC
Max. consumption: 0.5W
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Process temp.: F: -40º to 176º, C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º, C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: IP68
Encl. material: Polypropylene
Encl. cap material: Clear polycarbonate
Enclosure vent: Water tight membrane
Conduit entrance: 1/2” NPT
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Process mount: 06-0001: 2” NPT, 06-0011: 2” G, 12-0001: 3″ NPT, 12-0011: 3″ G
Mount gasket: -0001: N/a, -0011: Viton®
Classification: General purpose
Approval: UL 61010-1
Compliance: CE, RoHS
EchoPod®
DL14

The general purpose ultrasonic multi-function level transmitter provides continuous level measurement up to 49.2” (1.25m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming, non-condensing or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include chemical feed, skid or machine, IBC or drum and small waste sumps.
Range: 49.2” (1.25m)
Accuracy: 0.125” (3mm)
Resolution: 0.019” (0.5mm)
Dead band: 2” (5cm)
Beam width: 2” (5cm)
Configuration: WebCal™ PC, Windows®, USB 2.0
Memory: Non-volatile
Supply voltage: 24 VDC (loop)
Consumption: 0.5W
Loop resist.: 400Ω max
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4mA
Signal fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
Contact type: (4) SPST relays, 1A
Contact fail-safe: Power loss: Hold last, Power on: Open, close or hold last
Hysteresis: Selectable
Process temp.: F: 20° to 140°, C: -7° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -31° to 140°, C: -35° to 60°
Pressure: MWP = 30 PSI (2 bar)
Enclosure rating: Type 6P, encapsulated, corrosion resistant & submersible
Encl. material: Polycarbonate
Strain relief mat.: Santoprene
Trans. material: PVDF
Cable jacket mat.: Polyurethane
Cable type: 9-conductor, shielded
Cable length: 48” (1.2m)
Process mount: 1” NPT (1” G)
Mount gasket: Viton®
Classification: General purpose
Compliance: CE, RoHS
Approvals: cFMus
EchoPod® DL14 Multi-Function Ultrasonic Liquid Level Sensor
EchoPod®
DL10

The general purpose ultrasonic level transmitter provides continuous level measurement up to 49.2” (1.25m) with a 4-20 mA signal output, and is configured via our WebCal software. Select this sensor for small tanks with non-foaming, non-condensing or highly vaporous media such as chemical, water, wastewater and oil. Typical applications include chemical feed, skid or machine, IBC or drum and small waste sumps.
Range: 49.2” (1.25m)
Accuracy: 0.125” (3mm)
Resolution: 0.019” (0.5mm)
Dead band: 2” (5cm)
Beam width: 2” (5cm)
Configuration: WebCal™ PC, Windows®, USB 2.0
Memory: Non-volatile
Supply voltage: 24 VDC (loop)
Consumption: 0.5W
Loop resist.: 400Ω max
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4mA
Loop fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
Process temp.: F: 20° to 140°, C: -7° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -31° to 140°, C: -35° to 60°
Pressure: MWP = 30 PSI (2 bar)
Enclosure rating: Type 6P, encapsulated, corrosion resistant & submersible
Encl. material: Polycarbonate
Strain relief mat.: Santoprene
Trans. material: PVDF
Cable jacket mat.: Polyurethane
Cable type: 4-conductor, shielded
Cable length: 48” (1.2m)
Process mount: 1” NPT (1” G)
Mount gasket: Viton®
Classification: General purpose
Compliance: CE, RoHS
Approvals: cFMus