80 GHz Radar Sensors | Liquid & Solids | General Purpose

EchoBeam®
LR80

echoBeam-LR80 (2)

PERFORMANCE

EchoBeam® is the most reliable and easy-to-use non-contact level sensor transmitter. Flowline’s 80 GHz radar technology is unaffected by most media, process or environmental factors, and our intuitive LevelTapTM App makes configuration simple.

APPLICATION

The LR80 general purpose 80 GHz radar level sensor transmitter provides continuous level measurement up to 32.8’ (10m) for liquids or 16.4’ (5m) for solids with a 4-20 mA signal output. The level sensor transmitter is wirelessly configured over Bluetooth via our LevelTapTM App which enables you to see the level, verify the status, and manage the settings of connected level sensor transmitters from the safety of the ground or nearby catwalk. The level sensor transmitter measures liquid and solids media with a dielectric constant value ≥ 1.6, such as water, chemical or petroleum-based liquids, and pellet, grain, powder or aggregate solids. Select this level sensor transmitter for tank, sump, lift station, weir, canal, reservoir, bin, conveyor or transfer station applications.

Specification

Maximum range: Liquid: 32.8’ (10m) with media dielectric ≥ 20 and no agitation; Solids: 16.4’ (5m) with media dielectric ≥ 6 and no dust

Frequency: 80 GHz., W-band, FMCW

Accuracy: 0.4m to 10m: ± 5mm; 0.00m to 0.39m: ± 10mm

Dead band: 0” (0mm)

Beam angle: 8°

Min. dielectric: ≥ 1.6

Bluetooth version: Bluetooth 5.0

Bluetooth range: 26.2′ (8m)

Configuration: LevelTap™ App (iOS & Android)

Memory: Non-volatile

Signal output: 4-20 mA, two-wire

Max. signal dist: 1,000’ (304m)

Signal fail-safe: Selectable high, low or hold last value

Supply voltage: 12-30 VDC

Max. consumption: 22.5 mA

Process temp.: F: -40º to 140º; C: -40º to 60º

Temp. comp.: Automatic

Storage temp.: F: -40° to 176°, C: -40° to 80°

Pressure: -14.5 to 43.5 psi (-1 to 3 bar)

Enclosure rating: Type 6P (IP68)

Encl. material: PVDF (pigmented polyvinylidene fluoride)

Antenna material: PVDF (natural polyvinylidene fluoride)

Cable jacket mat.: PVC (polyvinyl chloride)

Cable seal mat.: Viton GLT (fluoroelastomer)

Cable orientation: Vertical

Shielded cable: 2-conductor

Cable length: 32.8’ (10m)

Conduit connect.: 1” NPT or 1” G

Process mount: 1 1/2” NPT or 1 1/2” G

Mount gasket: Viton GLT (fluoroelastomer) for G thread only

Classification: General purpose (cCSAus)

Approvals: C22.2 No. 61010-1-12

Compliance: FCC: Part 15.256, 15.209, 15C; ISED IC: RSS-102, RSS-211, RSS-247; UKCA RER 2017: 6(1)(a), 6(1)(b), 6(2); CE/RED 2014/53/EU: EN 302 372, EN 302 729, EN 301 489-1, -33, EN 300 328; SRRC: (No. [2002] 353); RoHS, REACH, CRN, conflict minerals

Download Datasheet

EchoBeam®
LR81

echoBeam-LR80 (2)

PERFORMANCE

EchoBeam® is the most reliable and easy-to-use non-contact level sensor transmitter. Flowline’s 80 GHz radar technology is unaffected by most media, process or environmental factors, and our intuitive LevelTapTM App makes configuration simple.

APPLICATION

The LR81 general purpose 80 GHz radar level sensor transmitter provides continuous level measurement up to 98.4’ (30m) for liquids or 49.2’ (15m) for solids, with a 4-20 mA with HART, Modbus or SDI-12 signal output. The level sensor transmitter is wirelessly configured over Bluetooth via our LevelTapTM App which enables you to see the level, verify the status, and manage the settings of connected level sensor transmitters from the safety of the ground or nearby catwalk. The level sensor transmitter measures liquid and solids media with a dielectric constant value ≥ 1.6, such as water, chemical or petroleum-based liquids, and pellet, grain, powder or aggregate solids. Select this level sensor transmitter for tank, sump, lift station, weir, canal, reservoir, silo, bin, conveyor, transfer station or stockpile applications.

Specification

Maximum range: Liquid: 98.4’ (30m) with media dielectric ≥ 20 and no agitation; Solids: 49.2’ (15m) with media dielectric ≥ 6 and no dust

Frequency: 80 GHz., W-band, FMCW

Accuracy: 0.4m to 30m: ± 2mm; 0.00m to 0.39m: ± 10mm

Dead band: 0” (0mm)

Beam angle: 8°

Min. dielectric: ≥ 1.6

Bluetooth version: Bluetooth 5.0

Bluetooth range: 26.2′ (8m)

Configuration: LevelTap™ App (iOS & Android)

Memory: Non-volatile

Signal output: 4-20 mA, two-wire, HART 7 or Modbus, RS485, 9600 baud or SDI-12

Max. signal dist: 4-20 mA: 1,000’ (304m); Modbus: 3,937’ (1200m); SDI-12: 2,000’ (609m) divided by number of sensors on the network

Signal fail-safe: Selectable high, low or hold last value

Supply voltage: 4-20 mA: 12-30 VDC; Modbus: 9-27 VDC; SDI-12: 9-30 VDC

Max. consumption: 4-20 mA: 22.5 mA; Modbus & SDI-12: 1.5 watt

Process temp.: F: -40° to 176°, C: -40° to 80°

Temp. comp.: Automatic

Storage temp.: F: -40° to 176°, C: -40° to 80°

Pressure: -14.5 to 43.5 psi (-1 to 3 bar)

Enclosure rating: Type 6P (IP68)

Encl. material: PVDF (pigmented polyvinylidene fluoride)

Antenna material: PVDF (natural polyvinylidene fluoride)

Cable jacket mat.: PVC (polyvinyl chloride)

Cable seal mat.: Viton GLT (fluoroelastomer)

Cable orientation: Vertical or horizontal

Shielded cable: 4-20 mA: 2-conductor; Modbus: 4-conductor; SDI-12: 3-conductor

Cable length: 32.8’ (10m)

Conduit connect.: 1” NPT or 1” G

Process mount: 1 1/2” NPT or 1 1/2” G

Mount gasket: Viton GLT (fluoroelastomer) for G thread only

Classification: General purpose (cCSAus)

Approvals: C22.2 No. 61010-1-12

Compliance: FCC: Part 15.256, 15.209, 15C; ISED IC: RSS-102, RSS-211, RSS-247; UKCA RER 2017: 6(1)(a), 6(1)(b), 6(2); CE/RED 2014/53/EU: EN 302 372, EN 302 729, EN 301 489-1, -33, EN 300 328; SRRC: (No. [2002] 353); RoHS, REACH, CRN, conflict minerals

Download Datasheet

EchoBeam®
LR83

echoBeam-LR80 (1)

PERFORMANCE

EchoBeam® is the most reliable and easy-to-use non-contact level sensor transmitter. Flowline’s 80 GHz radar technology is unaffected by most media, process or environmental factors, and our intuitive LevelTapTM App makes configuration simple.

APPLICATION

The LR83 general purpose 80 GHz radar level sensor transmitter provides continuous level measurement up to 98.4’ (30m) for liquids or 49.2’ (15m) for solids, with a 4-20 mA with HART or Modbus signal output. The level sensor transmitter is wirelessly configured over Bluetooth via our LevelTapTM App which enables you to see the level, verify the status, and manage the settings of connected level sensor transmitters from the safety of the ground or nearby catwalk. The level sensor transmitter measures liquid and solids media with a dielectric constant value ≥ 1.6, such as water, chemical or petroleum-based liquids, and pellet, grain, powder or aggregate solids. Select this sensor for tank, sump, weir, canal, reservoir, silo, bin, conveyor or stockpile applications.

Specification

Maximum range: Liquid: 98.4’ (30m) with media dielectric ≥ 20 and no agitation; Solids: 49.2’ (15m) with media dielectric ≥ 6 and no dust

Frequency: 80 GHz., W-band, FMCW

Accuracy: 0.4m to 30m: ± 2mm; 0.00m to 0.39m: ± 10mm

Dead band: 0” (0mm)

Beam angle: 6°

Min. dielectric: ≥ 1.6

Bluetooth version: Bluetooth 5.0

Bluetooth range: 26.2′ (8m)

Configuration: LevelTapTM App (IOS & Android) or push button

Memory: Non-volatile

Display type: LCD, dot matrix

Signal output: 4-20 mA, two-wire, HART 7 or Modbus, RS485, 9600 baud

Max. signal dist.: 4-20 mA: 1,000’ (304m); Modbus: 3,937’ (1200m)

Signal fail-safe: Selectable high, low or hold last value

Wire interface: 4-20 mA: 2-pole terminal block; Modbus: 4-pole terminal block

Supply voltage: 4-20 mA: 12-30 VDC; Modbus: 9-27 VDC

Max. consumption: 4-20 mA: 22.5 mA; Modbus: 1.5 watt

Process temp.: F: -40° to 212°, C: -40° to 100°

Temp. comp.: Automatic

Storage temp.: F: -40° to 176°, C: -40° to 80°

Pressure: -14.5 to 43.5 psi (-1 to 3 bar)

Enclosure rating: NEMA 4X (IP66/67)

Conduit connect.: NPT thread: 1/2” NPT; G thread: M20

Encl. material: PBT-FR (polybutylene terephthalate)

Encl. cap material: PC (clear polycarbonate)

Antenna material: PVDF (natural polyvinylidene fluoride)

Process mount: 1 1/2” NPT or 1 1/2” G

Mount gasket: Viton GLT (fluoroelastomer) for G thread only

Classification: General purpose (cCSAus)

Approvals: C22.2 No. 61010-1-12

Compliance: FCC: Part 15.256, 15.209, 15C; ISED IC: RSS-102, RSS-211, RSS-247; UKCA RER 2017: 6(1)(a), 6(1)(b), 6(2); CE/RED 2014/53/EU: EN 302 372, EN 302 729, EN 301 489-1, -33, EN 300 328; SRRC: (No. [2002] 353); RoHS, REACH, CRN, conflict minerals

Download Datasheet

EchoBeam®
LR85

echoBeam-LR80 (3)

PERFORMANCE

EchoBeam® is the most reliable and easy-to-use non-contact level sensor transmitter. Flowline’s 80 GHz radar technology is unaffected by most media, process or environmental factors, and our intuitive LevelTapTM App makes configuration simple.

APPLICATION

The LR85 general purpose 80 GHz radar level sensor transmitter provides continuous level measurement up to 196.8’ (60m) for solids or 393.7’ (120m) for liquids, with a 4-20 mA with HART or Modbus signal output. The level sensor transmitter is wirelessly configured over Bluetooth via our LevelTapTM App which enables you to see the level, verify the status, and manage the settings of connected level sensor transmitters from the safety of the ground or nearby catwalk. The level sensor transmitter measures solids and liquid media with a dielectric constant value ≥ 1.6, such as pellet, grain, powder or aggregate solids, and water, chemical or petroleum-based liquids. Select this level sensor transmitter for tall dusty silos and bunkers or difficult liquid process applications.

Specification

Maximum range: Solids: 196.8’ (60m) with media dielectric ≥ 6 and minimal dust; Liquid: 393.7’ (120m) with media dielectric ≥ 20 and minimal agitation

Frequency: 80 GHz., W-band, FMCW

Accuracy: 0.4m to 30m: ± 2mm; 0.00m to 0.39m: ± 10mm

Dead band: 0” (0mm)

Beam angle: 4°

Min. dielectric: ≥ 1.6

Bluetooth version: Bluetooth 5.0

Bluetooth range: 26.2′ (8m)

Configuration: LevelTapTM App (IOS & Android) or push button

Memory: Non-volatile

Display type: LCD, dot matrix

Signal output: 4-20 mA, two-wire, HART 7 or Modbus, RS485, 9600 baud

Max. signal dist: 4-20 mA: 1,000’ (304m); Modbus: 3,937’ (1200m)

Signal fail-safe: Selectable high, low or hold last value

Wire interface: 4-20 mA: 2-pole terminal block; Modbus: 4-pole terminal block

Supply voltage: 4-20 mA: 12-30 VDC; Modbus: 9-27 VDC

Max. consumption: 4-20 mA: 22.5 mA; Modbus: 1.5 watt

Process temp.: F: -40° to 248°; C: -40° to 120°

Temp. comp.: Automatic

Storage temp.: F: -40° to 176°, C: -40° to 80°

Pressure: Thread: -14.5 to 43.5 psi (-1 to 3 bar); Flange: Atmospheric

Enclosure rating: NEMA 4X (IP66/67)

Conduit connect.: NPT thread: 1/2” NPT; G thread: M20

Encl. material: PBT-FR (polybutylene terephthalate)

Encl. cap material: PC (clear polycarbonate)

Antenna material: PFA (natural perfluoroalkoxy)

Flange material: 316L (stainless steel)

Process mount: 3” NPT or M80x3 with Viton GLT gasket or 3” ANSI gimbal flange or DIN80 PN6 gimbal flange

Air purge conn.: 1/4” tube compression fitting (flange only)

Classification: General purpose (cCSAus)

Approvals: C22.2 No. 61010-1-12

Compliance: FCC: Part 15.256, 15.209, 15C; ISED IC: RSS-102, RSS-211, RSS-247; UKCA RER 2017: 6(1)(a), 6(1)(b), 6(2); CE/RED 2014/53/EU: EN 302 372, EN 302 729, EN 301 489-1, -33, EN 300 328, SRRC: (No. [2002] 353), RoHS, REACH, CRN, conflict minerals

Download Datasheet

26 GHz Radar Sensors | Liquids | General Purpose

EchoPulse®
LR30

download

The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA signal output, and is configured via its remote push button display module. The non-contact liquid level sensor is intended for industrial wastewater, municipal storm or sewer lift station, reservoir, river, canal or open channel applications located below or above grade. Select this sensor for challenging process conditions that may include light surface foam or agitation, small trash or plant material, wind, condensation or vapor. Each comes with a 32.8’ (10m) cable, mounting bracket and display module. The sensor is designed for bracket mount installation suspended above the liquid level.

Specification

Range: 12” to 98.4’ (30cm to 30m)

Frequency: 26 GHz.

Accuracy: ± 3mm

Dead band: 12” (30cm)

Beam angle: 12º

Supply voltage: 16-26 VDC

Max. consumption: 22.5 mA

Signal output: 4-20 mA, two-wire

Signal invert: 4-20 mA, 20-4 mA

Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA

Process temp.: F: -40º to 212º, C: -40º to 100º

Temp. comp.: Automatic

Pressure: Atmospheric

Enclosure rating: IP68

Encl. material: Nylon

Cable type: 6-conductor, shielded

Cable length: 32.8’ (10m)

Cable jacket mat.: PVC

Process mount: 304 bracket or 1” NPT

DISPLAY

Display type: LCD, dot matrix

Display units: Feet and meters

Display bar: Percent of span

Display graph: Echo signal curve

Configuration: Push button

Enclosure type: Wall mount

Enclosure rating: IP67

Encl. material: Polycarbonate

Conduit entrance: (2) 1/2” NPT connectors

COMMON

Memory: Non-volatile

Storage temp.: F: -40º to 176º, C: -40º to 80º

Classification: General purpose

Certification: cTUVus, FCC

Compliance: CE, RoHS

EchoPulse®
LR10

lr10-315x315

The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical or water storage applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for easy process conditions with corrosive media, light agitation, condensation or vapor, and installation in a low-profile tank adapter or flange fitting. Typical applications include chemical bulk storage and tanker trucks.

Specification

Range: 12” to 32.8’ (30cm to 10m)

Frequency: 26 GHz.

Accuracy: ± 5mm

Dead band: 12” (30cm)

Beam angle: 22º

Configuration: Push button

Memory: Non-volatile

Display type: LCD, dot matrix

Display units: Feet and meters

Display bar: Percent of span

Display graph: Echo signal curve

Supply voltage: 16-26 VDC

Max. consumption: 22.5 mA

Signal output: 4-20 mA, two-wire

Signal invert: 4-20 mA, 20-4 mA

Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA

Process temp.: F: -40º to 266º, C: -40º to 130º

Temp. comp.: Automatic

Storage temp.: F: -40º to 176º, C: -40º to 80º

Pressure: -14.5 to 43.5 psi (-1 to 3 bar)

Enclosure rating: IP67

Encl. material: Aluminum w/silicone gasket, PBT FR neck & wrench flat

Encl. window mat.: Polycarbonate

Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug

Antenna material: PFA

Process mount: 1 1/2” NPT

Classification: General purpose

Certification: cTUVus, FCC

Compliance: CE, RoHS

EchoPulse®
LR15

lr15-420x420

The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for petroleum, water, wastewater and diluted chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with diluted or non-corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a tank adapter, flange fitting or metal stand-pipe. Typical applications include bulk storage, tanker truck, process tank, waste sump and neutralization tanks.

Specification

Range: 12” to 98.4’ (30cm to 30m)

Frequency: 26 GHz.

Accuracy: ± 3mm

Dead band: 12” (30cm)

Beam angle: – 20: 18º, – 30: 12º, – 40: 8º

Configuration: Push button

Memory: Non-volatile

Display type: LCD, dot matrix

Display units: Feet and meters

Display bar: Percent of span

Display graph: Echo signal curve

Supply voltage: 16-26 VDC

Max. consumption: 22.5 mA

Signal output: 4-20 mA, two-wire

Signal invert: 4-20 mA, 20-4 mA

Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA

Process temp.: F: -76º to 302º, C: -60º to 150º

Temp. comp.: Automatic

Storage temp.: F: -40º to 176º, C: -40º to 80º

Pressure: -14.5 to 150 psi (-1 to 10 bar)

Enclosure rating: IP67

Encl. material: Aluminum w/silicone gasket

Encl. window mat.: Polycarbonate

Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug

Antenna material: 316L

Process mount: 1 1/2” NPT

Classification: General purpose

Certification: cTUVus, FCC

Compliance: CE, CRN, RoHS

EchoPulse®
LR20

lr20-420x420

The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks.

Specification

Range: 12” to 65.6’ (30cm to 20m)

Frequency: 26 GHz.

Accuracy: ± 3mm

Dead band: 12” (30cm)

Beam angle: – 30: 12º, – 40: 8º

Configuration: Push button

Memory: Non-volatile

Display type: LCD, dot matrix

Display units: Feet and meters

Display bar: Percent of span

Display graph: Echo signal curve

Supply voltage: 16-26 VDC

Max. consumption: 22.5 mA

Signal output: 4-20 mA, two-wire

Signal invert: 4-20 mA, 20-4 mA

Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA

Process temp.: F: -40º to 302º, C: -40º to 150º

Temp. comp.: Automatic

Storage temp.: F: -40º to 176º, C: -40º to 80º

Pressure: -14.5 to 72 psi (-1 to 5 bar)

Enclosure rating: IP67

Encl. material: Aluminum w/silicone gasket

Encl. window mat.: Polycarbonate

Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug

Antenna material: 316L w/PTFE inner shield

Process mount: – 30: 3” flange (ANSI), – 40: 4” flange (ANSI)

Classification: General purpose

Certification: cTUVus, FCC

Compliance: CE, CRN, RoHS