ATM – Analog Pressure Transmitter

GetAttachment-1 Features
  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Materials: Stainless steel, Titanium
Specifications

Pressure measuring range (bar)

 0.1 … 0.5, (1)> 0.5 … 2> 2 … 25
Overpressure3 bar3 x FS (≥ 3 bar)3 x FS
Burst pressure, (5)> 200 bar> 200 bar> 200 bar
Accuracy, (6) (± % FS)≤ 0.5 / ≤ 0.25≤ 0.5 / ≤ 0.25 / ≤ 0.1≤ 0.5 / ≤ 0.25 / ≤ 0.1
Thermal shift 
(± % FS/°C)
   
Zero point 0 … 70°C≤ 0.06≤ 0.03≤ 0.015
Zero point -25 … 85°C≤ 0.08≤ 0.04≤ 0.02
Span 0 … 70°C≤ 0.015≤ 0.015≤ 0.015
Span -25 … 85°C≤ 0.02≤ 0.02≤ 0.02
Response time, (typ.)< 1ms / 10 … 90% FS< 1ms / 10 … 90% FS< 1ms / 10 … 90% FS
Long term stability, (7)< 0.5% FS / < 4 mbar< 0.2% FS / < 4 mbar< 0.1% FS / < 0.2% FS
 > 25 … 600, (2), (4)> 600 … 1000, (2), (3)
Overpressure3 x FS (≤ 850 / ≤ 1500 bar)1500 bar
Burst pressure, (5)> 850 / ≤ 1500 bar> 1500 bar
Accuracy, (6) (± % FS)≤ 0.5 / ≤ 0.25 / ≤ 0.1≤ 1 / ≤ 0.5 / ≤ 0.25
Thermal shift 
(± % FS/°C)
  
Zero point 0 … 70°C≤ 0.015≤ 0.015
Zero point -25 … 85°C≤ 0.02≤ 0.02
Span 0 … 70°C≤ 0.015≤ 0.015
Span -25 … 85°C≤ 0.02≤ 0.02
Response time, (typ.)< 1ms / 10 … 90% FS< 1ms / 10 … 90% FS
Long term stability, (7)< 0.1% FS / < 0.2% FS< 0.1% FS / < 0.2% FS
Temperature range
  
Operating temperature-25 … 85°C
Process temperatur-40 … 150°C
Storage temperatur-25 … 85°C
Electrical specifications
 4 … 20 mA0 … 20 mA0 … 5 V / 0 … 10 V
Power supply9 … 33 VDC9 … 33 VDC15 … 30 VDC
Supply influence< 0.1% FS< 0.1% FS< 0.1% FS
Current consumption   
Circuit diagramATM - Analog Pressure Transmitter 1ATM - Analog Pressure Transmitter 2ATM - Analog Pressure Transmitter 3
Load resistanceATM - Analog Pressure Transmitter 4ATM - Analog Pressure Transmitter 5ATM - Analog Pressure Transmitter 6
Load influence< 0.1% FS< 0.1% FS< 0.1% FS
Physical specifications

Customer Benefits
  • Fast customization thanks to configurable product design
  • Any measuring ranges between 0…100mbar and 0…1000bar available
  • Demountable electrical connector option to allow adjustment of zero and span setting in the field
  • Compact design requires minimal space
  • Short response time suitable for dynamic pressure measurements

DOCUMENTATION